10kV SGB Series VPI Dry-Type Transformer (Nomex Insulation & High Safety Design)

The 10kV SGB series dry-type transformer is a high-performance transformer designed for harsh environments, high fire-safety requirements, and fluctuating load conditions.

Unlike cast resin transformers, the SGB series adopts VPI (Vacuum Pressure Impregnation) technology combined with NOMEX insulation, providing excellent thermal performance, superior safety, and long service life.

The 10kV SGB series dry-type transformer is a high-performance transformer designed for harsh environments, high fire-safety requirements, and fluctuating load conditions.

Unlike cast resin transformers, the SGB series adopts VPI (Vacuum Pressure Impregnation) technology combined with NOMEX insulation, providing excellent thermal performance, superior safety, and long service life.

It is especially suitable for environments with:

  • High humidity
  • Heavy pollution
  • Large load fluctuations
  • Strict fire safety requirements

Typical applications include:

  • Airports and power plants
  • Metallurgical industries
  • Hospitals and high-rise buildings
  • Commercial centers
  • Petrochemical and nuclear facilities

๐Ÿ”น Standards Compliance

  • IEC 60076-11 โ€“ Dry-Type Power Transformers
  • GB/T 1094.1 โ€“ Power Transformers
  • GB/T 1094.11 โ€“ Dry-Type Transformers
  • GB/T 10228 โ€“ Technical Requirements for Dry-Type Transformers
  • JB/T 10088 โ€“ Sound Levels of 6kVโ€“500kV Transformers
  • GB 20052-2020 โ€“ Energy Efficiency Standards

๐Ÿ”น Key Features

โœ” Excellent Thermal Performance

  • Superior heat dissipation
  • Long thermal lifespan
  • Supports 120% continuous overload under IP45 conditions without forced cooling

โœ” Exceptional Fire Safety

  • Flame-retardant materials
  • No smoke emission even under 800ยฐC high-temperature exposure

๐Ÿ‘‰ Ideal for fire-sensitive environments


โœ” Strong Thermal Shock Resistance

  • Can withstand sudden full-load operation at 50ยฐC ambient temperature

โœ” 100% Moisture & Water Resistance

  • Fully sealed insulation system
  • Excellent hydrophobic and anti-moisture properties

๐Ÿ‘‰ Suitable for humid and polluted environments


โœ” Ultra-Low Partial Discharge

  • Optimized winding structure
  • Strong electric field control

๐Ÿ‘‰ Ensures stable and long-term operation


โœ” Energy Saving & Eco-Friendly

  • Low loss and high efficiency
  • Recyclable insulation materials after service life

โœ” Intelligent Monitoring

  • Real-time operation monitoring
  • Optional remote communication system

๐Ÿ”น Structural Design

๐Ÿ”ธ Insulation System

  • High-performance NOMEX insulation (DuPont)
  • VPI vacuum pressure impregnation process
  • Multi-cycle baking and curing

โžก Benefits:

  • High thermal class (Class H)
  • Excellent mechanical strength
  • Long service life

๐Ÿ”ธ Windings

  • High-voltage winding: continuous winding structure
  • Low-voltage winding: robust conductor design

โžก Features:

  • Strong short-circuit resistance
  • Efficient cooling performance

๐Ÿ”ธ Core

  • High-quality grain-oriented silicon steel
  • 45ยฐ step-lap structure
  • Elastic fixing between core and winding

โžก Advantages:

  • Reduced no-load loss
  • Low noise operation

๐Ÿ”ธ Mechanical Structure

  • Elastic support system reduces vibration
  • Rigid clamping structure improves stability

๐Ÿ”ธ Terminals

  • Top-mounted terminals
  • Mid-position tap changer
  • Plate-type low-voltage terminals with argon arc welding

๐Ÿ”น Applications

  • Airports and transportation hubs
  • Power plants and substations
  • Metallurgical and heavy industries
  • Hospitals and high-rise buildings
  • Petrochemical and nuclear facilities
  • Coastal and high-humidity environments

๐Ÿ”น Advantages Summary

  • VPI + NOMEX insulation system
  • Excellent fire resistance and safety
  • Strong overload and thermal shock performance
  • Fully moisture-proof and pollution-resistant
  • Low partial discharge and high reliability
  • Maintenance-friendly and long service life

โ“ FAQ

1๏ธโƒฃ What is the difference between SGB and SCB transformers?

  • SGB: VPI + NOMEX insulation (non-cast type)
  • SCB: Epoxy resin cast insulation

๐Ÿ‘‰ SGB is better for moist, polluted, and high-temperature environments, while SCB is better for indoor safety applications.


2๏ธโƒฃ Can the SGB transformer operate in humid environments?

Yes, it features:

  • Hydrophobic insulation
  • Moisture resistance
  • Fully sealed design

๐Ÿ‘‰ Ideal for coastal and high-humidity areas.


3๏ธโƒฃ Does it require forced cooling?

No, under normal conditions:

  • Can operate at full load without forced cooling
  • Supports overload operation

4๏ธโƒฃ Is remote monitoring available?

Yes, it supports:

  • Temperature monitoring
  • Alarm and protection system
  • Remote communication

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “10kV SGB Series VPI Dry-Type Transformer (Nomex Insulation & High Safety Design)”

Il tuo indirizzo email non sarร  pubblicato. I campi obbligatori sono contrassegnati *